Skip to content
BITMAIN
AR1903 — image 1 of 6
ANTMINER

SPOTAR1903

Function
BTC/BCH/BSV SHA256
Specifications
1028TW | 24kW | 4 S19 XP Hyd. and Rack | 45℃ Heating Capacity
Cooling
Hydro-Cooling
Weight
406.2 kg
Price
$3,916
Shipping Date
Shipping in 20 working days after fully paid

For orders of 100 units or more, use Bulk Order.

| Specifications for AR1903


Product Glance Value
Model ANTRACK
Version AR21
Capacity 4 units ANTMINER (Hydro) or
2 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro) 
Maximum load,kW 24
Total load,kW 26
Detailed Characteristics Value
Part 1: Mining Cabinet  
Hardware Configuration  

Size (Length*Width*Height), mm (without package)

1260*600*1185

Size (Length*Width*Height), mm (with package)

1320*760*1320

Net weight, kg (without package)

138

Gross weight, kg (with package)

195

Network connection mode

RJ45 Ethernet 10/100M

Power Supply  
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump  

Rated power, W

450

Noise, dBA@1m

60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Part 2: External Cooler(1-3)  
Hardware Configuration  
Size (Length*Width*Height), mm (without package)

1197*650*1177

Size (Length*Width*Height), mm (with package)

1320*760*1320

Net weight, kg (without package)

112

Gross weight, kg (with package)

165

Power supply  
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 63
Fan  
Rated power, W

750

Noise, dBA@1m

60

Size (Length*Height*Thickness), mm

850*850*305

Environment Requirements  
Ambient temperature, °C -20~45
Water flow, L/min 32.0~40.0 
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 5
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(1-1) Caution: Wrong input voltage may probably cause miner damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.

| Specification Details For S19 XP Hyd.


Product Glance  
Model S19 XP Hyd.
Version 10
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(1-1) 257
Power on wall @35°C(1-2), Watt(1-1) 5,346
Power efficiency on wall @35°C(1-2), J/TH(1-1) 20.8
Detailed Characteristics  
Power Supply  
Phase 3
Input voltage, Volt(2-1) 380~415
Input Frequency Range, Hz 50~60
Input max current, Amp 12
Hardware Configuration  
Networking connection mode RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm 410*170*209
Server Size (Length*Width*Height, with package), mm 570*316*430
Net weight, kg(2-2) 12.8
Gross weight, kg 14.1
Environment Requirements  

Inlet coolant temperature,°C

20~40

Coolant flow, L/min

8.0~10.0

Coolant pressure, bar

≤3.5

Working coolant(2-2)

Antifreeze/ Pure water/Deionized water

Coolant pH value

Antifreeze: 7.0~9.0

Prue water: 6.5~7.5

Deionized water:8.5~9.5

Diameter of coolant pipe connector, mm

OD10
Storage temperature,°C -20~70
Operation humidity(non-condensing) , RH 10~90%

NOTE:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values.The actual hashrate value fluctuates by ± 3%, and the actual power on wall and powerefficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HW7 Liquid cooling container & Dry-cooling Tower product manual", Chapter 9, Article 3, Point 6, "Coolant Maintenance"!

PS: Please note that the Hydro-cooling miners are shipped without power cables. There are power cables inside the ANTRACK.