Skip to content
BITMAIN
ANTRACK AR22 — image 1 of 3
ANTMINER

SPOTANTRACK AR22

Function
BTC/BCH/BSV SHA256
Specifications
1Set | 24kW | 4 Hydro-cooling Miner Rack | 80℃ Heating Capacity
Cooling
Hydro-Cooling
Weight
456 kg
Price
$8,888
Shipping Date
Shipping in 20 working days after fully paid

For orders of 100 units or more, use Bulk Order.

| Specifications


Product Glance Value
Model ANTRACK
Version AR22
Capacity 4 units ANTMINER (Hydro) or
2 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro) 
Maximum load,kW 24
Detailed Characteristics Value
Part 1: Mining Cabinet  
Hardware Configuration  

Size (Length*Width*Height), mm (without package)

1200*600*1300

Size (Length*Width*Height), mm (with package)

1460*1330*780

Net weight, kg (without package)

132

Gross weight, kg (with package)

193

Network connection mode

RJ45 Ethernet 10/100M

Power Supply  
Power supply AC Input voltage, Volt(1-1) 380~415V AC
Power supply AC Input Frequency Range, Hz 50~60
Power supply AC Input current, Amp(1-2) 63
Water pump  

Rated power, W

450

Noise, dBA@1m

60
Lift, m 19
Size (Length*Width* Height), mm 360*210*268
Plate heat exchanger  
Maximum heat exchange power, kW 30
Size (Length*Width* Height), mm 305*106*64
Diameter of water pipe connector, mm

DN20

Part 2: External Cooler(1-3)  
Hardware Configuration  
Size (Length*Width*Height), mm (without package)

1370*555*1333

Size (Length*Width*Height), mm (with package)

1500*610*1880

Net weight, kg (without package)

225

Gross weight, kg (with package)

263

Power supply  
Power supply AC input voltage, Volt(1-1) 380~415V AC
Power supply AC input frequency range, Hz 50~60
Maximum power supply AC input current, Amp(1-2) 21
Heat pump  

Heating Capacity (typical), kW

32

Compressor Input (typical), kW

8

EER (typical)

3.0

Sound Level, Db(A)

50
Refrigerant R290
Heating water outlet temperature, °C 80
Fan  
Rated power, W

500

Noise, dBA@1m

50

Size (Length*Height*Thickness), mm

551*551*160

Water pump  
Rated power, W

180

Noise, dBA@1m

30

Size (Length*Width* Height), mm

130*551*129

Environment Requirements  
Ambient temperature, °C -20~40
Water flow, L/min 32.0~40.0 (Cabinet side)
Water flow, L/min 32.0~40.0 (Heating side)
Water pressure, bar ≤3.5
Working fluid(1-4) Organic Antifreeze (10%)
Installation distance, m(1-5) 5
Liquid PH 7.8~8.5
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

Notes:

(1-1) Caution: Wrong input voltage may probably cause miner damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler (heat pump) should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.